Estimation Formulas for Embedded-length of Connection Embedded-type Foundation Unit Modular System
DOI:
https://doi.org/10.29173/mocs245Abstract
Modular unit structure system has been used increasingly for mid-rise buildings where repetitive units are required. By assembling the pre-made modular unit structures, a building can be easily constructed. The assembled building must behave as one single structure to effectively transfer the forces and moments developed by gravity and lateral loads. For this, individual modular unit structure has to be properly connected to each other. Therefore, evaluation of the connection behavior of modular unit structure system is crucial. This study proposed the embedded steel column-to foundation connection for modular unit structure system and evaluated the behavior of the proposed connection. A series of experiments was performed to investigate the effect of embedment depth of the column, the shape of the end plate, and the shear studs in the embedded region of the column on the connection behavior. Finally, a design equation for the proposed connection was suggested.
Downloads
Published
Issue
Section
License
Copyright (c) 2015 Keum-Sung Park, Sang-Sup Lee, Sung-Yub Hong, Kyu-Woong Bae

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
MOC Summit Proceedings are distributed under a Creative Commons Attribution-NonCommercial-NoDerivs (CC BY-NC-ND) license that allows others to download these proceedings and share them with others with an acknowledgement of the work's authorship and initial publication in these proceedings. These proceedings may not be changed in any way or used commercially.